Nonlinear (Pushover) Analysis of Steel frame with External Bracing
N.T. Bhagat1, A. H. Deshmukh2
1Mr. N.T. Bhagat, Post Graduated Student, Structural Engineering Department, Civil Engineering, Collage of Engineering and Technology Akola (MH).
2Prof. A.H. Deshmukh, Assistant Professor of Civil Engineering Department, Collage of Engineering and Technology Akola (MH).

Manuscript received on April 03, 2015. | Revised Manuscript received on April 16, 2015. | Manuscript published on April 31, 2015. | PP: 12-16 | Volume-2 Issue-5, April 2015. | Retrieval Number: E0287042515
Open Access | Ethics and Policies | Cite
© The Authors. Published By: Blue Eyes Intelligence Engineering and Sciences Publication (BEIESP). This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/)

Abstract: Steel is by far most useful material for building construction in the world and in last decades steel structure has played an important role in construction industry. Providing strength, stability and ductility are major purposes of seismic design. It is necessary to design a structure to perform well under seismic loads. In this paper nonlinear pushover analysis is carried out for high rise building steel frame with different pattern of External bracing. The shear capacity of the structure can be increased by introducing steel bracing in structural. There is ‘n’ number of possibilities to arrange steel bracing for Ex. Diagonal, X, K, V Inverted V. A typica12th- story regular steel frame having ‘V’ zone building is designed for various types of concentric bracings like Diagonal, V, X, and Exterior X in that ‘X’ Bracing are more effective. So result shows effective bracing only using STAAD PRO for bracing using different types of material sections i.e. ISMB, ISMC and ISA or any tubular or hollow sections are used to compare for same patterns of bracin.
Keywords: Typical steel frame, exterior bracing Tube or ISMB or ISA or ISMC, Pushover Curve.